Hydraulic Products, TLX Couplings & Nipples

Series 607 - ¾”

TLX is a Flat-Face twist lock coupling for the toughest applications in the construction and demolition segment. This super-duty quick connect coupling is designed to work with the highest surge flows and the toughest pressure impulses. TLX is made from high alloy steels with Zinc-Nickel surface treatment for a long life in the harshest conditions. The Series is available in sizes from ½” to 1 ½” to cover most applications.


- The couplings and nipples are also available in 4 other sizes: ½” (Series 507), 1” (Series 707), 1 ¼” (Series 807) and 1 ½” (Series 907) https://www.cejn.com/globalassets/documents/brochures/tlx-en.pdf (TLX product folder PDF)

Series 607 - ¾”
Couplings Part No. Connection
Female thread 10 607 1101 106071101Rc 3/4"
 10 607 1103 106071103Rc 1"
 10 607 1203 106071203G 1"
 10 607 1301 106071301G 3/4"
 10 607 1231 106071231G 3/4" JIS ORB
 10 607 1401 1060714013/4" NPT
 10 607 1601 1060716011 1/16"-12 UN (3/4" SAE)


Nipples Part No. Connection
Female thread 10 607 6101 106076101Rc 3/4"
 10 607 6103 106076103Rc 1"
 10 607 6301 106076301G 3/4"
 10 607 6203 106076203G 1"
 10 607 6231 106076231G 3/4" JIS ORB
 10 607 6401 1060764013/4" NPT
 10 607 6601 1060766011 1/16"-12 UN (3/4" SAE)


Check with an authorized CEJN distributor for availability and prices. Other connections and sealing material on request. Some part numbers may be subject to minimum order quantities. CEJN reserves the right to make changes without further notification. Thread connections are listed according to ISO Standards. All measurements are in mm.
Technical data
Flow rate: 169 l/min (37.2 GPM) @ 3bar ΔP **
Temperature range: -30°C — +100°C (-22°F — +212°F)
Material coupling: High alloy steels with Zinc-Nickel surface
Material nipple: High alloy steels with Zinc-Nickel surface
Material seal: Nitrile (NBR)
Max. working pressure connected: 420 bar (6091 PSI)
Max. working pressure disconnected: 400 bar (5801 PSI)
Min. burst pressure connected: 1680 bar (24366 PSI)
Min. burst pressure disconnected: 1000 bar (14503 PSI)
Connectability: Connection with residual pressure only limited by operator strength
Disconnection under pressure: Disconnection with residual pressure in the system is allowed

(**) - If the application is constantly above this flow rate on respective coupling size, a larger coupling size should be considered to avoid too high pressure drop. The couplings can handle much higher flow rate during short time periods, but there is a risk of heat build-up in the system. Surge flows far above normal flow rate is in general not a problem.

- TLX is pressure impulse tested at 525 bar (7614 psi) for 1.000.000 impulses acc. to ISO 7241-2. (Flow Rate) - If the application is constantly above this flow rate on respective coupling size, a larger coupling size should be considered to avoid too high pressure drop. The couplings can handle much higher flow rate during short time periods, but there is a risk of heat build-up in the system. Surge flows far above normal flow rate is in general not a problem.

Pressure drop chart
Series 607 - ¾”

Available files for download