Hydraulic Products, TLX Couplings & Nipples
Series 707 TLX - 1”
TLX is a Flat-Face twist lock coupling for the toughest applications in the construction and demolition segment. This super-duty quick connect coupling is designed to work with the highest surge flows and the toughest pressure impulses. TLX is made from high alloy steels with Zinc-Nickel surface treatment for a long life in the harshest conditions. The Series is available in sizes from ½” to 1 ½” to cover most applications.
The couplings and nipples are also available in 4 other sizes: ½” (Series 507), ¾” (Series 607), 1 ¼” (Series 807) and 1 ½” (Series 907) http://www.cejn.com/upload/download/Brochures/tlx-twist-lock-series/TLX-en.pdf (TLX product folder PDF)
| Couplings | Part No. | Connection |
| Female thread | 10 707 1103 107071103 | |
| 10 707 1104 107071104 | ||
| 10 707 1203 107071203 | ||
| 10 707 1204 107071204 | ||
| 10 707 1233 107071233 | ||
| 10 707 1403 107071403 | ||
| 10 707 1603 107071603 | ||
| Nipples | Part No. | Connection |
| Female thread | 10 707 6103 107076103 | |
| 10 707 6104 107076104 | ||
| 10 707 6203 107076203 | ||
| 10 707 6204 107076204 | ||
| 10 707 6233 107076233 | ||
| 10 707 6403 107076403 | ||
| 10 707 6603 107076603 | ||
| Technical data | |
| 291 l/min (64.0 GPM) @ 3bar ΔP ** | |
| -30°C — +100°C (-22°F — +212°F) | |
| High alloy steels with Zinc-Nickel surface | |
| High alloy steels with Zinc-Nickel surface | |
| Nitrile (NBR) | |
| 420 bar (6091 PSI) | |
| 400 bar (5801 PSI) | |
| 1680 bar (24366 PSI) | |
| 1000 bar (14503 PSI) | |
| Connection with residual pressure only limited by operator strength | |
| Disconnection with residual pressure in the system is allowed | |
(**) - If the application is constantly above this flow rate on respective coupling size, a larger coupling size should be considered to avoid too high pressure drop. The couplings can handle much higher flow rate during short time periods, but there is a risk of heat build-up in the system. Surge flows far above normal flow rate is in general not a problem.
- TLX is pressure impulse tested at 7614 PSI (525 bar) for 1.000.000 impulses acc. to ISO 7241-2.
(Flow Rate) - If the application is constantly above this flow rate on respective coupling size, a larger coupling size should be considered to avoid too high pressure drop. The couplings can handle much higher flow rate during short time periods, but there is a risk of heat build-up in the system. Surge flows far above normal flow rate is in general not a problem.