Hydraulic Products, TLX Couplings & Nipples
Series 907 TLX - 1 ½”
TLX is a flat-face twist lock coupling for the toughest applications in the construction and demolition segment. This super-duty quick connect coupling is designed to work with the highest surge flows and the toughest pressure impulses. TLX is made from high alloy steels with Zinc-Nickel surface treatment for a long life in the harshest conditions. The Series is available in sizes from ½”” to 1 ½” to cover most applications.
The couplings and nipples are also available in 4 other sizes: ½” (Series 507) ¾” (Series 607) 1” (Series 707) and 1¾” (Series 807) https://www.cejn.com/globalassets/documents/brochures/tlx-twist-lock-series/tlx-en.pdf (TLX product folder PDF)
Couplings | Part No. | Connection |
Female thread | 10 907 1105 109071105 | |
10 907 1205 109071205 | ||
10 907 1207 109071207 | ||
10 907 1235 109071235 | ||
10 907 1405 109071405 | ||
10 907 1407 109071407 | ||
10 907 1605 109071605 | ||
10 907 1607 109071607 | ||
Nipples | Part No. | Connection |
Female thread | 10 907 6105 109076105 | |
10 907 6205 109076205 | ||
10 907 6207 109076207 | ||
10 907 6235 109076235 | ||
10 907 6405 109076405 | ||
10 907 6407 109076407 | ||
10 907 6605 109076605 | ||
10 907 6607 109076607 | ||
Technical data | |
740 l/min (162.8 GPM) @ 3bar ΔP ** | |
-30°C — +100°C (-22°F — +212°F) | |
High alloy steels with Zinc-Nickel surface | |
High alloy steels with Zinc-Nickel surface | |
Nitrile (NBR) | |
380 bar (5511 PSI) | |
380 bar (5511 PSI) | |
1520 bar (22045 PSI) | |
1000 bar (14503 PSI) | |
Connection with residual pressure only limited by operator strength | |
Disconnection with residual pressure in the system is allowed |
(**) - If the application is constantly above this flow rate on respective coupling size, a larger coupling size should be considered to avoid too high pressure drop. The couplings can handle much higher flow rate during short time periods, but there is a risk of heat build-up in the system. Surge flows far above normal flow rate is in general not a problem.
- TLX is pressure impulse tested at 475 bar (6889 psi) for 1.000.000 impulses acc. to ISO 7241-2.
(Flow Rate) - If the application is constantly above this flow rate on respective coupling size, a larger coupling size should be considered to avoid too high pressure drop. The couplings can handle much higher flow rate during short time periods, but there is a risk of heat build-up in the system. Surge flows far above normal flow rate is in general not a problem.