Hydraulic Products, TLX Couplings & Nipples
Series 507 TLX - ½”
TLX is a Flat-Face twist lock coupling for the toughest applications in the construction and demolition segment. This super-duty quick connect coupling is designed to work with the highest surge flows and the toughest pressure impulses. TLX is made from high alloy steels with Zinc-Nickel surface treatment for a long life in the harshest conditions. The Series is available in sizes from ½” to 1 ½” to cover most applications.
- The couplings and nipples are also available in 4 other sizes: ¾” (Series 607) 1” (Series 707) 1 ¼” (Series 807) and 1 ½ ” (Series 907) https://www.cejn.com/globalassets/documents/brochures/tlx-twist-lock-series/tlx-en.pdf (TLX product folder PDF)
Coupling | Part No. | Connection |
Female thread | 10 507 1105 105071105 | |
10 507 1107 105071107 | ||
10 507 1205 105071205 | ||
10 507 1207 105071207 | ||
10 507 1235 105071235 | ||
10 507 1405 105071405 | ||
10 507 1407 105071407 | ||
10 507 1605 105071605 | ||
10 507 1607 105071607 | ||
Nipples | Part No. | Connection |
Female thread | 10 507 6105 105076105 | |
10 507 6107 105076107 | ||
10 507 6205 105076205 | ||
10 507 6207 105076207 | ||
10 507 6235 105076235 | ||
10 507 6405 105076405 | ||
10 507 6407 105076407 | ||
10 507 6605 105076605 | ||
10 507 6607 105076607 | ||
Technical data | |
93 l/min (20.5 GPM) @ 3bar ΔP ** | |
-30°C — +100°C (-22°F — +212°F) | |
High alloy steels with Zinc-Nickel surface | |
High alloy steels with Zinc-Nickel surface | |
Nitrile (NBR) | |
420 bar (6091 PSI) | |
420 bar (6091 PSI) | |
1680 bar (24366 PSI) | |
1050 bar (15229 PSI) | |
Connection with residual pressure only limited by operator strength | |
Disconnection with residual pressure in the system is allowed |
(**) - If the application is constantly above this flow rate on respective coupling size, a larger coupling size should be considered to avoid too high pressure drop. The couplings can handle much higher flow rate during short time periods, but there is a risk of heat build-up in the system. Surge flows far above normal flow rate is in general not a problem.
- TLX is pressure impulse tested at 525 bar (7614 psi) for 1.000.000 impulses acc. to ISO 7241-2.
(Flow Rate) - If the application is constantly above this flow rate on respective coupling size, a larger coupling size should be considered to avoid too high pressure drop. The couplings can handle much higher flow rate during short time periods, but there is a risk of heat build-up in the system. Surge flows far above normal flow rate is in general not a problem.